Von Duprin CXA99EO Chexit Delayed Egress Rim Exit Device
Product Info
The Von Duprin Chexit device is designed for controlled egress applications. It meets both life safety and security needs, as well as the requirements of NFPA 101 for “Special Locking Arrangement” and IBC “Special Egress-Control Devices”. All control inputs, auxiliary locking, local alarm and remote signaling outputs are self-contained in the Chexit assembly. Numerous configurable options allow the device to be customized for the specific code or application requirements. The standard Chexit device sounds an alarm and keeps the door secured for 15 seconds following an exit attempt with immediate release upon fire.
The Chexit device includes a 6” x 20” decal for application on door. “PUSH UNTIL ALARM SOUNDS. DOOR CAN BE OPENED IN 15 SECONDS”
Chexit typical applications
Chexit single door with options – The Chexit is used as an access control device. The card reader allows access. Also shown in this application is an external horn and door position switch. The auxiliary horn is used for increased volume in remote locations. Using a door position switch gives added security to the opening in case the door is not reclosed.
With the Chexit disarmed, the opening functions as a normal exit device. If card readers are required on both sides of the door, the normally closed contacts of the readers should be wired in series.
Specifications / Power supply requirements
Input voltage – 24VDC
Input current inrush – 1.25A
Input current holding – 390mA
Alarm relay and Secure relay contact ratings – 24VDC, 1A
Fire alarm, Inhibit and Door position switch inputs require normally closed dry contacts.
Power supply information for CX devices with motor driven blocking actuator
Power supply – Maximum number of devices
PS902 (up to 2 amps) – 1 Chexit device
PS904 (up to 4 amps) – 3 Chexit devices
PS906 (up to 6 amps) – 4 Chexit devices
PS914 (up to 4 amps) – 4 Chexit devices
EO = Exit Only, ANSI Function 01 (98/99 Series Outside Trim Sold Separately)
For use with single doors or double doors with mullions
Deadlocking latchbolt standard
Minimum door opening sizes for CX devices: 3’0” = 2’10-3/4” – 4’0” = 3’4-3/4”
299 Roller Strike Standard
ANSI/BHMA Certified, Grade-1
UL listed for panic exit hardware (F model UL listed for fire hardware)
Requires 1-1/4” mortise cylinder (sold separately)